|
Twitter
|
Facebook
|
Google+
|
VKontakte
|
LinkedIn
|
Viadeo
|
English
|
Français
|
Español
|
العربية
|
 
International Journal of Innovation and Applied Studies
ISSN: 2028-9324     CODEN: IJIABO     OCLC Number: 828807274     ZDB-ID: 2703985-7
 
 
Wednesday 08 May 2024

About IJIAS

News

Submission

Downloads

Archives

Custom Search

Contact

  • Contact us
  • Newsletter:

Connect with IJIAS

  Now IJIAS is indexed in EBSCO, ResearchGate, ProQuest, Chemical Abstracts Service, Index Copernicus, IET Inspec Direct, Ulrichs Web, Google Scholar, CAS Abstracts, J-Gate, UDL Library, CiteSeerX, WorldCat, Scirus, Research Bible and getCited, etc.  
 
 
 

Assessment of health risks linked to the use of rainwater collected and stored in a concrete tank: Case of the storage Ivory sud, Fianarantsoa, Madagascar


[ Évaluation des risques sanitaires liée à l’utilisation de l’eau de pluie récupérée et stockée dans une cuve en béton: Cas du site de stockage Ivory sud, Fianarantsoa, Madagascar ]

Volume 40, Issue 3, September 2023, Pages 613–621

 Assessment of health risks linked to the use of rainwater collected and stored in a concrete tank: Case of the storage Ivory sud, Fianarantsoa, Madagascar

Andry Hariniaina RABEARISOA1, Anasthasie Miharisoa JIBO2, Hajandrainy RABEARISOA3, Bruno RAZANAMPARANY4, Sedravola Nasolo RANDIMBIARISON5, Ravo Victoire NASOLOMAMPIONONA6, and Faralahy Paul RAMALAZA7

1 Sciences et technologies, Ecole Normale Supérieur, Fianarantsoa, Madagascar
2 Laboratoire de chimie, Université d’Ankatso, Antananarivo, Madagascar
3 Sciences et technologies, Ecole Normale Supérieur, Fianarantsoa, Madagascar
4 Laboratoire de chimie, Université d’Ankatso, Antananarivo, Madagascar
5 Sciences et technologies, Ecole Normale Supérieur, Fianarantsoa, Madagascar
6 Sciences et technologies, Ecole Normale Supérieur, Fianarantsoa, Madagascar
7 Sciences et technologies, Ecole Normale Supérieur, Fianarantsoa, Madagascar

Original language: French

Copyright © 2023 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract


Numerous studies have shown the variability of the physico-chemical and microbiological characteristics of meteorite waters collected and stored in recovery tanks. This variability can have negative impacts for users, physico-chemical and microbiological analyzes reflecting the quality of rainwater collected downstream from the roof and stored in a concrete tank were carried out. The chosen site is a rainwater tank whose use is not limited to laundry, some households use it for washing, for domestic uses in the kitchen, and even for drinking. The objective of this work is to assess the risks to which users are exposed when consuming collected and stored rainwater. The hydrogen potential analysis revealed an average content of 7.05. The turbidity value is less than 5NTU.The conductivity has an average value of 0,01005 µs/cm. The quantity of chloride ion is very varied for each sample analyzed, with an average of 227.47 mg/l in Cl-. The samples show considerable number of total coliforms.

Author Keywords: rainwater, recovery, physicochemical quality, health risk.


Abstract: (french)


Nombreuses études ont montré la variabilité de la caractéristique physico-chimique et microbiologique des eaux météorites collecté et stockée dans des cuves de récupérations. Cette variabilité pouvant avoir des impacts négatifs pour les utilisateurs, des analyses physico-chimiques et microbiologique traduisant la qualité d’une eau pluviale collectée en avale de toiture et conserver dans une cuve en béton ont été effectué. Le site choisi est un réservoir d’eau de pluie dont l’usage ne se limite pas à la lessive, certains ménages l’utilisent pour la toilette, pour les usages domestiques en cuisine, et même pour la consommation. L’objectif de ce travail est d’évaluer les risques auxquels s’exposent les usagers à la consommation de l’eau de pluie récupéré et stockée. L’analyse du potentiel hydrogène a révélé une teneur moyenne de 7,05. La valeur de la turbidité est inférieure à 5NTU. La conductivité a une valeur moyenne de 0,01005µs/cm. La quantité d’ion chlorure est très varié pour chaque échantillon analysé, avec une moyenne de 227,47 mg/l en Cl-. Les échantillons présentent un nombre considérable de coliformes totaux.

Author Keywords: eau de pluie, récupération, qualité physico-chimique, risque sanitaire.


How to Cite this Article


Andry Hariniaina RABEARISOA, Anasthasie Miharisoa JIBO, Hajandrainy RABEARISOA, Bruno RAZANAMPARANY, Sedravola Nasolo RANDIMBIARISON, Ravo Victoire NASOLOMAMPIONONA, and Faralahy Paul RAMALAZA, “Assessment of health risks linked to the use of rainwater collected and stored in a concrete tank: Case of the storage Ivory sud, Fianarantsoa, Madagascar,” International Journal of Innovation and Applied Studies, vol. 40, no. 3, pp. 613–621, September 2023.