Comparison between two models of the battery storage used in the photovoltaic system


[ Comparaison de deux modèles de batterie utilisés dans les systèmes photovoltaïques ]

Volume 20, Issue 4, July 2017, Pages 1033–1041

 Comparison between two models of the battery storage used in the photovoltaic system

Safa Hakim1, Mustapha Elyaqouti2, Lahoussine Bouhouch3, and Ali Moudden4

1 LMTI, Département de physiques, Université Ibn Zohr, B.P 8100, 80000 Agadir, Morocco
2 ERTIAER, EST d'Agadir, Université Ibn Zohr, Agadir, Morocco
3 ERTAIER, Ecole Supérieure de Technologie d'Agadir (ESTA), Université Ibn Zohr, Agadir, Morocco
4 LMTI, Département de Physique, Université Ibn Zohr, Agadir, Morocco

Original language: French

Copyright © 2017 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract


In the stand-alone PV, the energy is generated only by the PV panels. Therefore, during the night or in periods with low solar radiation, it is essential to put a battery bank to store the captured energy to ensure power supply. To highlight the physical phenomena that govern the operation of the storage system, we proposed in this paper to study the battery modeling. This work is devoted to the modeling and simulation under the Matlab / Simulink environment of two electric battery models; Namely the CIEMAT model (Centro de Investigaciones Energéticas, Mediomientales y Technologicas) and the simplified electric model PSpice. In order to verify the validity of these mathematical models, the results of the numerical simulation are compared with the experimental data of the solar Varta battery.

Author Keywords: Battery storage, modeling, CIEMAT Model, Pspice Model, solar Varta.


Abstract: (french)


Dans le PV autonome, l'énergie est générée uniquement par les panneaux photovoltaïques. Par conséquent, pendant la nuit ou dans les périodes de faible rayonnement solaire, il est essentiel de mettre un banc de batterie pour stocker l'énergie capturée pour assurer l'alimentation. Pour mettre en évidence les phénomènes physiques qui régissent le fonctionnement du système de stockage, nous avons proposé dans ce papier d'étudier la modélisation de la batterie. Ce travail est consacré à la modélisation et à la simulation sous l'environnement Matlab/Simulink de deux modèles de batterie électrique ; à savoir le modèle CIEMAT (Centro de Investigaciones Energéticas, Mediombientales y Technologicas) et le modèle électrique simplifié PSpice. Afin de vérifier la validité de ces modèles mathématiques, les résultats de la simulation numérique sont comparés avec les données expérimentales de la batterie Varta solaire.

Author Keywords: Système de stockage, Modélisation, Modèle de CIEMAT, Modèle PSpice, Varta solaire.


How to Cite this Article


Safa Hakim, Mustapha Elyaqouti, Lahoussine Bouhouch, and Ali Moudden, “Comparison between two models of the battery storage used in the photovoltaic system,” International Journal of Innovation and Applied Studies, vol. 20, no. 4, pp. 1033–1041, July 2017.