Modeling of condensate water system in a nuclear power plant with new control strategy using Dymola/Modelica


Volume 5, Issue 2, February 2014, Pages 82–88

 Modeling of condensate water system in a nuclear power plant with new control strategy using Dymola/Modelica

Jibran Baladi1, Naeem Ullah Khan2, Muhammad Junaid Rabbani3, Muhammad Shoib Khan4, and Syed Muhammad Amaad Asghar5

1 Department of Electrical Engineering, Karlstad University, Karlstad, Varmland, Sweden
2 Department of Electrical Engineering, Karlstad University, Karlstad, Varmland, Sweden
3 Department of Electrical Engineering, Karlstad University, Karlstad, Varmland, Sweden
4 Department of Electrical Engineering, Karlstad University, Karlstad, Varmland, Sweden
5 Department of Electrical Engineering, Karlstad University, Karlstad, Varmland, Sweden

Original language: English

Copyright © 2014 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract


This paper is focused on modeling and introducing a new control strategy for a condensate water system. Current control strategy of the system is simple feedback control system with one PID controller. Results of current control strategy were taken into account for improvements in terms of system stability, valve movements and unwanted transients. Problems found in condensate system were; large variations in process variable, extra movement in valve positions and inefficient opening of valves. Simulation model with current control strategy and results as of real power plant was created and validated, as new control strategy can be applied and results can be compared. The main recommendation to improve the control system performance was found through PID cascade control strategy that could assist the current controller. The recommendation was evaluated by designing and implementing the cascade control strategy on the Dymola simulation model. Simulation results pointed out considerable increase in system performance according to the requirements of Ringhals (Vattenfall) AB Sweden.

Author Keywords: Condensate, valve movements, validated, Dymola, transients.


How to Cite this Article


Jibran Baladi, Naeem Ullah Khan, Muhammad Junaid Rabbani, Muhammad Shoib Khan, and Syed Muhammad Amaad Asghar, “Modeling of condensate water system in a nuclear power plant with new control strategy using Dymola/Modelica,” International Journal of Innovation and Applied Studies, vol. 5, no. 2, pp. 82–88, February 2014.