[ Caractérisation qualitative et quantitative des eaux usées de la ville Aïn Taoujdate (Maroc) et impact sur le fonctionnement de la station d'épuration de type lagunage ]
Volume 20, Issue 2, May 2017, Pages 675–680
Abdelaziz BOUHLAL1, Abdelkader CHAHLAOUI2, and Jawad BOUZID3
1 Equipe de Gestion et Valorisation des Ressources Naturelles, Laboratoire d’Environnement et Santé, Département de Biologie, Faculté des Sciences, Université Moulay Ismail, Meknès, Morocco
2 Equipe de Gestion et Valorisation des Ressources Naturelles, Laboratoire d’Environnement et Santé, Département de Biologie, Faculté des Sciences, Université Moulay Ismail, Meknès, Morocco
3 Equipe de Gestion et Valorisation des Ressources Naturelles, Laboratoire d’Environnement et Santé, Département de Biologie, Faculté des Sciences, Université Moulay Ismail, Meknès, Morocco
Original language: French
Copyright © 2017 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
The present study had the main objective, the quantitative and qualitative characterization of the raw wastewater of STEP Aïn Taoujdate (Morocco) in term of debit and of concentration of the parameters of pollution (TSS, COD and BOD5) which correspond to some given by entries essential for purification processes. On this base, a monthly monitoring in the order of sample a month during 2012, on 2013 and 2014. Also, the medium stocks in 2012 is in the order of 1230 m3 / j (debit), 408 mg / l (TSS), 969 mgO2 / l (COD) and 528 mgO2 / l (BOD5); in 2013, is in the order of 1930 m3 / j (debit), 387 mg / l (TSS), 902 mgO2 / l (COD) and 503 mgO2 / l (BOD5) and in 2014, is in the order of 1859 m3 / j (debit), 475 mg / l (TSS), 1054mgO2 / l (COD) and 491 mgO2 / l (BOD5). Also, this station works in hydraulic load exceeding the reference debit of STEP (1500 m3 / j) with Concentrations of pollutants in the order of 13755 EH (population equivalent) exceeding the maximum theoretical pollutant load for which the station was designed (13330 EH) and make sign sometimes of a sub-capacity of the system of treatment.
Author Keywords: wastewater, WWTP, pollution, hydraulic load, population equivalent (PE).
Volume 20, Issue 2, May 2017, Pages 675–680
Abdelaziz BOUHLAL1, Abdelkader CHAHLAOUI2, and Jawad BOUZID3
1 Equipe de Gestion et Valorisation des Ressources Naturelles, Laboratoire d’Environnement et Santé, Département de Biologie, Faculté des Sciences, Université Moulay Ismail, Meknès, Morocco
2 Equipe de Gestion et Valorisation des Ressources Naturelles, Laboratoire d’Environnement et Santé, Département de Biologie, Faculté des Sciences, Université Moulay Ismail, Meknès, Morocco
3 Equipe de Gestion et Valorisation des Ressources Naturelles, Laboratoire d’Environnement et Santé, Département de Biologie, Faculté des Sciences, Université Moulay Ismail, Meknès, Morocco
Original language: French
Copyright © 2017 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract
The present study had the main objective, the quantitative and qualitative characterization of the raw wastewater of STEP Aïn Taoujdate (Morocco) in term of debit and of concentration of the parameters of pollution (TSS, COD and BOD5) which correspond to some given by entries essential for purification processes. On this base, a monthly monitoring in the order of sample a month during 2012, on 2013 and 2014. Also, the medium stocks in 2012 is in the order of 1230 m3 / j (debit), 408 mg / l (TSS), 969 mgO2 / l (COD) and 528 mgO2 / l (BOD5); in 2013, is in the order of 1930 m3 / j (debit), 387 mg / l (TSS), 902 mgO2 / l (COD) and 503 mgO2 / l (BOD5) and in 2014, is in the order of 1859 m3 / j (debit), 475 mg / l (TSS), 1054mgO2 / l (COD) and 491 mgO2 / l (BOD5). Also, this station works in hydraulic load exceeding the reference debit of STEP (1500 m3 / j) with Concentrations of pollutants in the order of 13755 EH (population equivalent) exceeding the maximum theoretical pollutant load for which the station was designed (13330 EH) and make sign sometimes of a sub-capacity of the system of treatment.
Author Keywords: wastewater, WWTP, pollution, hydraulic load, population equivalent (PE).
Abstract: (french)
La présente étude avait l’objectif principal, la caractérisation quantitative et qualitative de l’eau usée brute de la STEP Aïn Taoujdate (Maroc) en terme de débit et de concentrations de paramètres de pollution (MES, DCO et DBO5) qui correspondent à certaines donnés d’entrées essentielles aux processus épuratoires. Sur cette base, un suivi mensuel de l’ordre d’un prélèvement par mois durant les années 2012, 2013 et 2014. Aussi, les valeurs moyennes enregistrées en 2012 est de l’ordre de 1230 m3/j (débit), 408 mg/l (MES), 969 mgO2/l (DCO) et 528 mgO2/l (DBO5) ; en 2013 est de l’ordre de 1930 m3/j (débit), 387 mg/l (MES), 902 mgO2/l (DCO) et 503 mgO2/l (DBO5) puis en 2014, est de l’ordre de 1859 m3/j (débit), 475 mg/l (MES), 1054 mgO2/l (DCO) et 491 mgO2/l (DBO5). Par ailleurs, cette station fonctionne en charge hydraulique en 2013 et 2014 dépassant le débit de référence de la STEP (1500 m3/j) avec des concentrations de polluants de l’ordre de 13755 EH (équivalent habitant) dépassant la charge polluante théorique maximale pour laquelle la station a été conçue (13330 EH) et qui font signe parfois d’une sous-capacité du système de traitement.
Author Keywords: eaux usées, STEP, pollution, charge hydraulique, équivalent habitant (EH).
How to Cite this Article
Abdelaziz BOUHLAL, Abdelkader CHAHLAOUI, and Jawad BOUZID, “Qualitative and quantitative characterization of wastewater of the Aïn Taoujdate city (Morocco) and the impact on the functioning of the lagoon-type wastewater treatment plant,” International Journal of Innovation and Applied Studies, vol. 20, no. 2, pp. 675–680, May 2017.