In view of the importance of squirrel cage induction machines in industrial applications, effective methods are needed to detect faults that could disrupt their operation. Despite their robustness, squirrel cage induction motors are subject to some faults, such as the broken bar. Current is one of the most widely used parameters for diagnosing squirrel cage induction motors. In most cases, however, the Motor Current Signature Analysis (MCSA) method is used. However, in the specific case of a broken bar, analysis of the current intensity in each rotor bar enables precise detection of a broken bar. The present work analyzes the evolution of the current intensity in each rotor bars in the case of a healthy rotor and in the presence of a broken bar. The current intensity in the rotor bar is strongly impacted, with a greatly reduced current. This situation also leads to a distribution of current intensity in the neighboring bars. As a result, the intensity of the current flowing through these bars increases according to their proximity to the faulty bar.