|
Twitter
|
Facebook
|
Google+
|
VKontakte
|
LinkedIn
|
Viadeo
|
English
|
Français
|
Español
|
العربية
|
 
International Journal of Innovation and Applied Studies
ISSN: 2028-9324     CODEN: IJIABO     OCLC Number: 828807274     ZDB-ID: 2703985-7
 
 
Friday 29 March 2024

About IJIAS

News

Submission

Downloads

Archives

Custom Search

Contact

  • Contact us
  • Newsletter:

Connect with IJIAS

  Now IJIAS is indexed in EBSCO, ResearchGate, ProQuest, Chemical Abstracts Service, Index Copernicus, IET Inspec Direct, Ulrichs Web, Google Scholar, CAS Abstracts, J-Gate, UDL Library, CiteSeerX, WorldCat, Scirus, Research Bible and getCited, etc.  
 
 
 

Environmental analysis of the sites of catchment of water of the REGIDESO in Kinshasa


[ Analyse environnementale des sites de captage d’eau de la REGIDESO à Kinshasa ]

Volume 25, Issue 1, December 2018, Pages 313–321

 Environmental analysis of the sites of catchment of water of the REGIDESO in Kinshasa

Joseph M. Kakundika1, Dieudonné E. Musibono2, Lambert K. Binzangi3, and Thierry T. Tangou4

1 Université de Kinshasa, RD Congo
2 Professeur ordinaire & Directeur du groupe ERGS, Département de l'Environnement, Faculté des sciences, Université de Kinshasa (UNIKIN), RD Congo
3 Département de Géographie et Environnement, UPN, Kinshasa, RD Congo
4 Laboratoire d’Ecotoxicologie et Santé des écosystèmes ERGS, Département des sciences de l’environnement, Faculté des Sciences, Université de Kinshasa, RD Congo

Original language: French

Copyright © 2018 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract


The environment (middle) of three important sites of catchment of water of the REGIDESO in Kinshasa notably the rivers N’djili and Lukunga and the Congo stream is in particular vulnerable following the failure to respect of the environmental hygiene by the riparian populations of these three sites and of all kinois in general. This survey proposes to verify the degree of water pollution treated by the REGIDESO and the efficiency of the treatment techniques applied by this one to purify water. For that to make, 3 samples by site of the raw water and three of water treated have been appropriated and have been analyzed in order to determine the physic-chemical parameters (MO, MES, Turbudité, pH, T°, SD, Co, NO-3, PO 4, FeT, Pb, OD, DBO5 and DCO) and bacteriological (fecal coliforms, fecal streptococci and Escherichia Colis) for the raw water, while for the treated water, it has about of the analysis of the data base of the laboratory of the REGIDESO. The gotten results show that the dismissals descended of the human activities upstream of the sources of catchment have negative impacts on water to treat and that some parameters as the total iron, the DCO and the MY don't answer the norms of the drinking water. Otherwise, the meticulous exam on one period of one year of the archives of the laboratory of the REGIDESO indicates some temporary, daily or periodic failings as for the bacteriology.

Author Keywords: site of water catchment, environmental hygiene, pollution, raw water, treated water.


Abstract: (french)


L’environnement (milieu) de trois sites importants de captage d’eau de la REGIDESO à Kinshasa notamment les rivières N’djili et Lukunga et le fleuve Congo est vulnérable suite au non-respect de l’hygiène environnementale par les populations riveraines de ces trois sites en particulier et de tous les kinois en général. Cette étude propose d’identifier les polluants potentiels de ces trois sites, de vérifier le degré de pollution de l’eau traitée par la REGIDESO et l’efficacité des techniques de traitement appliquées par celle-ci pour purifier l’eau. Pour ce faire, six échantillons de l’eau brute par site et six de l’eau traitée par usine ont été prélevés et analysés en vue de déterminer les paramètres physico-chimiques (MO, MES, Turb., pH, T°, SD, Co, NO-3, PO-4, FeT, Pb, OD, DBO5 et DCO) et bactériologiques (coliformes fécaux, streptocoques fécaux et Escherichia Coli) pour l’eau brute, tandis que pour l’eau traitée, il a s’agit de l’analyse de la base de données du laboratoire de la REGIDESO. Les résultats obtenus montrent que les rejets issus des activités anthropiques en amont des sources de captage ont des incidences négatives sur l’eau à traiter et que certains paramètres tels que le fer total, la DCO et les MES dans l’eau traitée ne répondent pas aux normes de l’eau potable. Par ailleurs, l’examen minutieux sur une période d’un an des archives du laboratoire de la REGIDESO indique certaines défaillances temporaires, journalières ou périodiques quant à la bactériologie.

Author Keywords: site de captage d’eau, hygiène environnementale, pollution, eau brute, eau traitée.


How to Cite this Article


Joseph M. Kakundika, Dieudonné E. Musibono, Lambert K. Binzangi, and Thierry T. Tangou, “Environmental analysis of the sites of catchment of water of the REGIDESO in Kinshasa,” International Journal of Innovation and Applied Studies, vol. 25, no. 1, pp. 313–321, December 2018.