[ Effet de la granulométrie de latérite sur la capacité épuratoire de réacteur garni de latérite et de sable ]
Volume 34, Issue 4, November 2021, Pages 814–825
A. Lydie C. Mangoua-Allali1, Amidou Traore2, Ali E. Kouadio3, and Lacina Coulibaly4
1 Unité de recherche en Biotechnologie et Ingénierie de l’Environnement, Université Nangui Abrogoua, Abidjan, Côte d’Ivoire
2 Unité de recherche en Biotechnologie et Ingénierie de l’Environnement, Université Nangui Abrogoua, Abidjan, Côte d’Ivoire
3 Laboratoire National d’Essais-Qualité Métrologique et d’Analyses, Abidjan, Côte d’Ivoire
4 Unité de recherche en Biotechnologie et Ingénierie de l'Environnement, Université Nangui Abrogoua, Abidjan, 02 BP 801 Abidjan 02, Côte d'Ivoire
Original language: French
Copyright © 2021 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
The objective of this study was to know the effect of particle size of the laterite contained in reactors filled with laterite and sand on the removal of the physicochemical parameters of a well water. Three reactors filled from the bottom to the top with 10 cm of granitic gravel, 50 cm of sand, 10 cm of standing water and 30 cm of different particles sizes of laterite (granular, very coarse and medium) were used. The depths of the sand and the standing water were fixed according to a previous study. pH, conductivity, turbidity, suspended solids, ammonium, nitrate, lead and total iron were analyzed according to standard norms. The results showed that pH increased with decreasing particle size while conductivity decreased. With regard to suspended solids and turbidity, the removal was (98.9%) and of the same order in all the reactors. Removal efficiency of ammonium ranged from 97.67% to 98.1% in the reactors. The reactors also removed nitrate, total iron and lead. In addition, the concentrations of nitrate, total iron and lead decreased with increasing particle size. However, the reactor filled with medium laterite and sand was the most efficient.
Author Keywords: Laterite, biosand, adsorption, filtration, physicochemical parameters, well.
Volume 34, Issue 4, November 2021, Pages 814–825
A. Lydie C. Mangoua-Allali1, Amidou Traore2, Ali E. Kouadio3, and Lacina Coulibaly4
1 Unité de recherche en Biotechnologie et Ingénierie de l’Environnement, Université Nangui Abrogoua, Abidjan, Côte d’Ivoire
2 Unité de recherche en Biotechnologie et Ingénierie de l’Environnement, Université Nangui Abrogoua, Abidjan, Côte d’Ivoire
3 Laboratoire National d’Essais-Qualité Métrologique et d’Analyses, Abidjan, Côte d’Ivoire
4 Unité de recherche en Biotechnologie et Ingénierie de l'Environnement, Université Nangui Abrogoua, Abidjan, 02 BP 801 Abidjan 02, Côte d'Ivoire
Original language: French
Copyright © 2021 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract
The objective of this study was to know the effect of particle size of the laterite contained in reactors filled with laterite and sand on the removal of the physicochemical parameters of a well water. Three reactors filled from the bottom to the top with 10 cm of granitic gravel, 50 cm of sand, 10 cm of standing water and 30 cm of different particles sizes of laterite (granular, very coarse and medium) were used. The depths of the sand and the standing water were fixed according to a previous study. pH, conductivity, turbidity, suspended solids, ammonium, nitrate, lead and total iron were analyzed according to standard norms. The results showed that pH increased with decreasing particle size while conductivity decreased. With regard to suspended solids and turbidity, the removal was (98.9%) and of the same order in all the reactors. Removal efficiency of ammonium ranged from 97.67% to 98.1% in the reactors. The reactors also removed nitrate, total iron and lead. In addition, the concentrations of nitrate, total iron and lead decreased with increasing particle size. However, the reactor filled with medium laterite and sand was the most efficient.
Author Keywords: Laterite, biosand, adsorption, filtration, physicochemical parameters, well.
Abstract: (french)
Cette étude avait pour objectif d’appréhender l’effet de la granulométrie de la latérite contenue dans des réacteurs garnis de latérite et de sable sur l’élimination des paramètres physico-chimiques d’une eau de puits. Pour se faire trois réacteurs remplis du bas vers le haut de 10 cm de gravier, 50 cm de sable, 10 cm de colonne d’eau surnageante et 30 cm de latérite de granulométrie différente (granule, très grossière et moyenne) ont été utilisés. Les hauteurs du sable et de la colonne d’eau surnageante ont été fixées suivant une étude antérieure. Le pH, la conductivité, la turbidité, les matières en suspension, l’ammonium, le nitrate, le plomb et le fer total ont été analysés selon les normes standard. Il ressort des résultats que le pH augmentait avec la diminution de la taille des grains contrairement à la conductivité qui diminuait. S’agissant des matières en suspension et de la turbidité, l’élimination était quasi-totale (98,9%) et de même ordre dans tous les réacteurs. Un rendement épuratoire assez élevé (98,1%; 97,67%; 97,24%) est noté pour l’ammonium respectivement dans les réacteurs garnis de latérite moyenne, très grossière et granule. Les réacteurs éliminaient également le nitrate, le fer total et le plomb. Par ailleurs, les concentrations en nitrate, fer total et plomb diminuaient parallèlement avec la granulométrie. Toutefois, le réacteur garni de latérite moyenne et de sable était le plus performant.
Author Keywords: Latérite, adsorption, sable, granulométrie, filtration, puits, paramètres physico-chimiques.
How to Cite this Article
A. Lydie C. Mangoua-Allali, Amidou Traore, Ali E. Kouadio, and Lacina Coulibaly, “Effect of particle size of laterite in efficiency of biosand laterite reactor,” International Journal of Innovation and Applied Studies, vol. 34, no. 4, pp. 814–825, November 2021.