|
Twitter
|
Facebook
|
Google+
|
VKontakte
|
LinkedIn
|
Viadeo
|
English
|
Français
|
Español
|
العربية
|
 
International Journal of Innovation and Applied Studies
ISSN: 2028-9324     CODEN: IJIABO     OCLC Number: 828807274     ZDB-ID: 2703985-7
 
 
Thursday 28 March 2024

About IJIAS

News

Submission

Downloads

Archives

Custom Search

Contact

  • Contact us
  • Newsletter:

Connect with IJIAS

  Now IJIAS is indexed in EBSCO, ResearchGate, ProQuest, Chemical Abstracts Service, Index Copernicus, IET Inspec Direct, Ulrichs Web, Google Scholar, CAS Abstracts, J-Gate, UDL Library, CiteSeerX, WorldCat, Scirus, Research Bible and getCited, etc.  
 
 
 

Relationships between lightning and rainfall intensities during rainy events in Benin


Volume 9, Issue 2, November 2014, Pages 765–776

 Relationships between lightning and rainfall intensities during rainy events in Benin

A. Joseph Adechinan1, B. Etienne Houngninou2, and Hilaire Kougbéagbédè3

1 Département de Physique, Faculté des Sciences et Techniques, Université d'Abomey-Calavi, Benin
2 Département de Physique, Faculté des Sciences et Techniques, Université d'Abomey-Calavi, Benin
3 Département de Physique, Faculté des Sciences et Techniques, Université d'Abomey-Calavi, Benin

Original language: English

Copyright © 2014 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract


This study aims at examining the impact of spatial resolution and the time lag on the relationship between the rainfall intensities and the cloud-to-ground lightning rate during rainy events that occurred in North of Benin in 2006. The lightning data used of this experiment have been collected by LINET network and the rain data are provided by a network of 23 rain gauges. The results obtained show that the temporal scales between the beginning of the electrical activity and precipitations are optimal when these letters are synchronized. The average optimal radius is identified at 8 km around the rain gauges location. In most cases (59 %), the maximum of electrical activity precedes the maximum of precipitations. The heavy rainfalls to ground are offset in time with regard to a peak of electrical activity with an average of 5 minutes.

Author Keywords: rain event, cloud-to-ground lightning, rainfall intensity, time lag, Benin.


How to Cite this Article


A. Joseph Adechinan, B. Etienne Houngninou, and Hilaire Kougbéagbédè, “Relationships between lightning and rainfall intensities during rainy events in Benin,” International Journal of Innovation and Applied Studies, vol. 9, no. 2, pp. 765–776, November 2014.