Volume 10, Issue 4, March 2015, Pages 1335–1349
E. A. Ayob1, D. M. El-zeer2, and O. S. Shehata3
1 Taif University, Faculty of Science and Education in Al-khurma (girls branch), Chemistry Dep., Al-khurma, KSA
2 Taif University, Faculty of Science and Education in Al-khurma (girls branch), Physics Dep., Al-khurma, KSA
3 Physical Chemistry Department, National Research Centre, Dokki, Giza, Egypt
Original language: English
Copyright © 2015 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Austinatic Stainless Steel is one of the most widely used biomaterials for implants process, In the present study chemical and physical treatment have been used on two types of austinatic Stainless, 316L and 310S to compare their corrosion performance on both samples before and after both treatments. Corrosion rate for two samples was decrease with both treatments; polarization is confirming the open circuit potential and weight loss results. Metallography was studied by electron microscopy and X-ray photoelectron spectroscopy (XPS) method to evaluate the effectiveness of the proposed method and to determine the chromium concentration in the surface layer after treatment.
Author Keywords: Stainless steel, Biomaterials, Chemical Treatment, Physical Treatment, XPS.
E. A. Ayob1, D. M. El-zeer2, and O. S. Shehata3
1 Taif University, Faculty of Science and Education in Al-khurma (girls branch), Chemistry Dep., Al-khurma, KSA
2 Taif University, Faculty of Science and Education in Al-khurma (girls branch), Physics Dep., Al-khurma, KSA
3 Physical Chemistry Department, National Research Centre, Dokki, Giza, Egypt
Original language: English
Copyright © 2015 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract
Austinatic Stainless Steel is one of the most widely used biomaterials for implants process, In the present study chemical and physical treatment have been used on two types of austinatic Stainless, 316L and 310S to compare their corrosion performance on both samples before and after both treatments. Corrosion rate for two samples was decrease with both treatments; polarization is confirming the open circuit potential and weight loss results. Metallography was studied by electron microscopy and X-ray photoelectron spectroscopy (XPS) method to evaluate the effectiveness of the proposed method and to determine the chromium concentration in the surface layer after treatment.
Author Keywords: Stainless steel, Biomaterials, Chemical Treatment, Physical Treatment, XPS.
How to Cite this Article
E. A. Ayob, D. M. El-zeer, and O. S. Shehata, “Corrosion protection of Stainless Steel Used in Orthopedic Implants by Chemical and Physical Treatment,” International Journal of Innovation and Applied Studies, vol. 10, no. 4, pp. 1335–1349, March 2015.