[ تأثير استخدام جهد زيتا في التقليل من نمو الطبقات الاحيائية في خزانات مياه الشرب ]
Volume 12, Issue 3, August 2015, Pages 552–558
Zainab Fouad Nadhem1, Akeel Kazim Alwan2, Manar Ahmed Ehmud3, Ahmed Aidan Al-Hussien4, Shatha Ali Shafiq5, Hayder Jasim Mohammad6, Jaafar Sadeq Murtadha7, and Ghania Ayaal8
1 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
2 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
3 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
4 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
5 Department of Biology, College of Science, Mustansiriyah University, Baghdad, Iraq
6 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
7 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
8 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
Original language: French
Copyright © 2015 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
The effects of zeta potential on drinking water tanks were studied to find a suitable and cheap method to conserve the water specification biologically by preventing the growth of biofilm inside the inner surfaces of the tanks without any additives. Three plastic tanks were used (1 m3 each); the first one is feed tank, the second is control tank and the third is connected with zeta rod (ZRS-R) that gives constant voltage (30
Author Keywords: Zeta potential, Zeta rod, Biofilm, bacteria colony, Suspended particles.
Volume 12, Issue 3, August 2015, Pages 552–558
Zainab Fouad Nadhem1, Akeel Kazim Alwan2, Manar Ahmed Ehmud3, Ahmed Aidan Al-Hussien4, Shatha Ali Shafiq5, Hayder Jasim Mohammad6, Jaafar Sadeq Murtadha7, and Ghania Ayaal8
1 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
2 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
3 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
4 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
5 Department of Biology, College of Science, Mustansiriyah University, Baghdad, Iraq
6 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
7 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
8 Ministry of Science and Technology, Environment & Water Research Directorate, Baghdad, Iraq
Original language: French
Copyright © 2015 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract
The effects of zeta potential on drinking water tanks were studied to find a suitable and cheap method to conserve the water specification biologically by preventing the growth of biofilm inside the inner surfaces of the tanks without any additives. Three plastic tanks were used (1 m3 each); the first one is feed tank, the second is control tank and the third is connected with zeta rod (ZRS-R) that gives constant voltage (30
Author Keywords: Zeta potential, Zeta rod, Biofilm, bacteria colony, Suspended particles.
Abstract: (french)
تطرق البحث إلى تأثير جهد زيتا على خزانات مياه الشرب وإيجاد طريقة سهلة وغير مكلفة للمحافظة على مواصفات المياه داخلها, وذلك بالتقليل من نمو الطبقات الإحيائية على أسطح الجدران الداخلية لها دون أي مضافات كيميائية, لأجراء التجارب تم نصب ثلاث خزانات بلاستيكية سعة 1م3 الخزان الأول هو خزان التغذية الرئيسي والثاني خزان السيطرة بالرمز(A) وهو بدون معالجة أما الخزان الثالث يزود بجهاز توليد جهد زيتا (ZRS-R) ثابت الفولتية (±30 كيلو فولت) بالرمز (B). يتم العمل بصورة مماثلة للحالة الفعلية من خزن واستهلاك يومي للماء, لتقيم النتائج درست المواصفات الفيزيائية (الأملاح الذائبة الكلية,التوصيلية الكهربائية, الأس الهيدروجيني, درجة الملوحة) وكذلك المواصفات البيولوجية المتضمنة في الكشف عن الأحياء المجهرية (البكتريا ,الفطريات والطحالب) العالقة في الماء والمسببة فيما بعد للطبقة الإحيائية. أثبت نتائج الفحوصات الفيزيائية تحسنا في مواصفات المياه المعرضة لجهد زيتا في الحد من الترسبات الملحية والطينية, أما الفحوصات البيولوجية كانت أفضل في تقييم أداء جهد زيتا بسبب النتائج المقاربة لقيمة (0)خلية بكتيرية و(0) خلية فطرية وكذلك انحسار نمو الطحالب في الخزان (B) عن خزان السيطرة (A)الذي كان لظهور المستعمرات البكتيرية والفطرية ظهورا واضحا.
Author Keywords: جهد زيتا, قطب زيتا, الطبقة الإحيائية, المستعمرات البكتيرية, الجسيمات الغروية.
How to Cite this Article
Zainab Fouad Nadhem, Akeel Kazim Alwan, Manar Ahmed Ehmud, Ahmed Aidan Al-Hussien, Shatha Ali Shafiq, Hayder Jasim Mohammad, Jaafar Sadeq Murtadha, and Ghania Ayaal, “The Effect of Using Zeta Potential to Prevent Biofilm from water Tanks,” International Journal of Innovation and Applied Studies, vol. 12, no. 3, pp. 552–558, August 2015.