[ Caractéristiques physicochimiques des eaux usées de la ville de M’rirt, (Maroc) ]
Volume 17, Issue 3, August 2016, Pages 791–803
Touria Hachi1, Maryama Hachi2, Hassan ECH-CHAFAY3, Mouhcine ELGHABASSI4, Hicham ETTAYEA5, Khadija Elkharrim6, Abderrazzak Khadmaoui7, and Driss Belghyti8
1 Laboratoire d'Environnement et Energies Renouvelables, Université Ibn Tofaïl, Faculté des Sciences, BP : 133, Kénitra, Morocco
2 Laboratoire de Biodiversité et Ressources Naturelles, Université Ibn Tofaïl, Faculté des Sciences, BP : 133, Kénitra, Morocco
3 Laboratoire de biotechnologie, environnement et qualité, Département de Biologie, Faculté des Sciences, Université Ibn Tofail, Kénitra, Morocco
4 Laboratoire de biotechnologie, environnement et qualité, Département de Biologie, Faculté des Sciences, Université Ibn Tofail, Kénitra, Morocco
5 Laboratoire de biotechnologie, environnement et qualité, Département de Biologie, Faculté des Sciences, Université Ibn Tofail, Kénitra, Morocco
6 Department of Biology, Ibn Tofail University, Faculty of Sciences, Environment and Renewable Energy Laboratory, Kenitra, BP 133, 14000, Morocco
7 Laboratoire de Génétique et Biométrie, Faculté des Sciences, Université Ibn Tofail, Kenitra, Morocco
8 Laboratoire Environnement et Energies Renouvelables, Faculté des Sciences, Université Ibn Tofail, B.P: 133, 14000 Kénitra, Morocco
Original language: French
Copyright © 2016 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
In order to assess the degree of pollution of wastewater from the city of M'rirt, we conducted during 2014; a study of physical and chemical characteristics of the waters of reference collector L6-Sp. it collects almost all wastewater from the city and is located right on the road to Meknes. The results showed that liquid waste is loaded into mineral matter in terms of electrical conductivity (Avg. = 3055,25?S / cm
Author Keywords: Sewage, collector, physicochemical parameters, M'rirt.
Volume 17, Issue 3, August 2016, Pages 791–803
Touria Hachi1, Maryama Hachi2, Hassan ECH-CHAFAY3, Mouhcine ELGHABASSI4, Hicham ETTAYEA5, Khadija Elkharrim6, Abderrazzak Khadmaoui7, and Driss Belghyti8
1 Laboratoire d'Environnement et Energies Renouvelables, Université Ibn Tofaïl, Faculté des Sciences, BP : 133, Kénitra, Morocco
2 Laboratoire de Biodiversité et Ressources Naturelles, Université Ibn Tofaïl, Faculté des Sciences, BP : 133, Kénitra, Morocco
3 Laboratoire de biotechnologie, environnement et qualité, Département de Biologie, Faculté des Sciences, Université Ibn Tofail, Kénitra, Morocco
4 Laboratoire de biotechnologie, environnement et qualité, Département de Biologie, Faculté des Sciences, Université Ibn Tofail, Kénitra, Morocco
5 Laboratoire de biotechnologie, environnement et qualité, Département de Biologie, Faculté des Sciences, Université Ibn Tofail, Kénitra, Morocco
6 Department of Biology, Ibn Tofail University, Faculty of Sciences, Environment and Renewable Energy Laboratory, Kenitra, BP 133, 14000, Morocco
7 Laboratoire de Génétique et Biométrie, Faculté des Sciences, Université Ibn Tofail, Kenitra, Morocco
8 Laboratoire Environnement et Energies Renouvelables, Faculté des Sciences, Université Ibn Tofail, B.P: 133, 14000 Kénitra, Morocco
Original language: French
Copyright © 2016 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract
In order to assess the degree of pollution of wastewater from the city of M'rirt, we conducted during 2014; a study of physical and chemical characteristics of the waters of reference collector L6-Sp. it collects almost all wastewater from the city and is located right on the road to Meknes. The results showed that liquid waste is loaded into mineral matter in terms of electrical conductivity (Avg. = 3055,25?S / cm
Author Keywords: Sewage, collector, physicochemical parameters, M'rirt.
Abstract: (french)
Dans le but d’évaluer le degré de pollution des eaux usées de la ville de M’rirt, nous avons mené, pendant l’année 2014, une étude des caractères physico-chimiques des eaux du collecteur de référence L6-Sp qui collecte presque la totalité des eaux usées de la ville et qu’est situé à la droite sur la route de méknes. Les résultats ont montrées que ce rejet liquide est très chargé en matière minérale en termes de conductivité électrique (Moy. = 3055,25µS/cm ±1428,79), en TDS (Moy= 1965,04mg/l±932,16), en turbidité (Moy=444,06 NTU±152,61), en Salinité (Moy=1,68mg/l±0,89) et en matière organique en terme de DCO (Moy. = 972,92 mg/L ±278,04), en DBO5 (Moy. = 492,92 mg/L±145,39), en MES (Moy. = 609,33± 494,00), avec des teneurs faible en oxygène dissous (Moy= 0,67mg/l±0,79) et en pourcentage de saturation en oxygène (Moy= 6,79% ±7,74). Le pH est proche de la neutralité (Moy= 7,18±0,36), la température est de 20,5°C (±4,33). Malgré que ces eaux usées présentent une charge organique élevée DBO5/DCO = 0,51, MES/DBO5 = 1,24, elles présentent une biodégradabilité satisfaisante. L’examen de DCO/DBO5 = 1,97 souligne bien le caractère biodégradable et l’origine domestique de ces eaux auxquelles un traitement biologique paraît tout à fait convenable. Aussi on a dévoilée d’après les résultats que les eaux usées de la ville sont concentrés et dépasse les normes de rejet national.
Author Keywords: Eaux usées, collecteur, paramètres physico-chimique, M’rirt.
How to Cite this Article
Touria Hachi, Maryama Hachi, Hassan ECH-CHAFAY, Mouhcine ELGHABASSI, Hicham ETTAYEA, Khadija Elkharrim, Abderrazzak Khadmaoui, and Driss Belghyti, “Physico-chemical characteristics of wastewater from the city of M'rirt, (Morocco),” International Journal of Innovation and Applied Studies, vol. 17, no. 3, pp. 791–803, August 2016.